EMEC MTOWER Cooling Tower & Evaporative Condenser Dosing System – Complete 3-Pump Package

ر.ع.3,500.000

Complete automatic cooling tower and evaporative condenser dosing system for commercial and industrial sites in Oman. The supply-only package combines the EMEC MTOWER controller with three dosing pumps, three chemical tanks, automatic blowdown control, water metering and monitoring accessories.

Description

Cooling Tower Dosing System Oman

Cooling tower dosing system Oman packages from UV Water Systems provide automatic chemical control for cooling towers and evaporative condensers using proven EMEC dosing technology.

The EMEC MTOWER cooling tower dosing system Oman package is designed for cooling towers and evaporative condensers that require controlled chemical dosing and automatic blowdown. It continuously monitors conductivity and coordinates bleed control, inhibitor dosing and two independent biocide programmes.

Accurate control helps maintain the selected cycles of concentration, reduce uncontrolled water loss and support the management of scale, corrosion and microbiological growth. The package is suitable for hotels, hospitals, shopping centres, factories and other commercial or industrial cooling-water systems in Oman.

Main features and benefits

  • EMEC MTOWER controller with backlit graphic display and rotary setup interface.
  • Conductivity monitoring with temperature compensation for automatic blowdown control.
  • Three EMEC chemical dosing pumps: one inhibitor pump and two independent biocide pumps.
  • Three chemical solution tanks for segregated chemical storage.
  • Motorised blowdown valve for automatic conductivity control.
  • Make-up water meter input for proportional inhibitor dosing and water-use monitoring.
  • Flow input prevents dosing when circulation flow is unavailable.
  • Chemical level inputs provide low-level alarm capability.
  • Configurable inhibitor control by feed-and-bleed, percentage of bleed, percentage of time, pulse water meter or PPM setup.
  • Two programmable biocide timers with 1, 2 or 4-week scheduling.
  • Alarms for high or low conductivity, bleed timeout, chemical level and flow.
  • IP65 (NEMA 4X) ABS enclosure for demanding plant-room conditions.

Scope of supply

  • 1 EMEC MTOWER cooling-tower controller
  • 3 EMEC chemical dosing pumps
  • 3 chemical solution tanks
  • 1 motorised blowdown valve
  • 1 make-up water meter with pulse output
  • Conductivity probe with temperature compensation
  • Flow sensor or flow switch
  • Injection valves and suction assemblies
  • Standard tubing and interconnecting accessories

Pump capacities, tank sizes, valve size and meter size will be selected according to the cooling-system volume, pipework and water-treatment programme.

MTOWER controller specifications

Parameter Specification
Application Cooling towers and evaporative condensers
Control functions Conductivity, bleed, inhibitor and two biocides
Display Backlit graphic LCD
Power supply Universal 90-265 VAC, 50/60 Hz
Average consumption 20 W
Enclosure IP65 / NEMA 4X, ABS
Operating temperature -10 to 50 °C
Relative humidity 0-95%, non-condensing
Conductivity output 0/20 or 4/20 mA
Temperature output 0/20 or 4/20 mA
Dimensions 325 x 255 x 226 mm

Commercial terms

Price: OMR 3,500.000 for supply only.

Not included: installation, commissioning, chemical supply, electrical power cabling, civil works, external plumbing, pipe modifications and site-specific supports. UV Water Systems can quote these services separately after a site assessment.

Why choose UV Water Systems?

UV Water Systems supplies engineered cooling-water treatment and dosing equipment across Oman. Our Muscat team helps customers select the correct pumps, tanks, valves, meters and controls for each cooling tower or evaporative condenser circuit, with technical support and spare-parts assistance.


نظام الجرعات الأوتوماتيكي لأبراج التبريد والمكثفات التبخيرية

نظام متكامل للتحكم الأوتوماتيكي في معالجة مياه أبراج التبريد والمكثفات التبخيرية للمشاريع التجارية والصناعية في سلطنة عمان. تشمل حزمة التوريد وحدة التحكم EMEC MTOWER وثلاث مضخات جرعات وثلاثة خزانات للمواد الكيميائية وصمام تصريف أوتوماتيكي وعداد مياه وأجهزة القياس والتحكم اللازمة.

يراقب النظام الموصلية الكهربائية للمياه باستمرار ويتحكم في عملية التصريف، كما يدير جرعات مادة مانع التآكل والترسبات وبرنامجين مستقلين للمبيدات الحيوية. يساعد التحكم الدقيق على الحفاظ على دورات التركيز المطلوبة وتقليل فقد المياه ودعم الحد من الترسّبات والتآكل والنمو الميكروبي.

المزايا الرئيسية

  • وحدة تحكم EMEC MTOWER بشاشة رسومية مضاءة.
  • قياس الموصلية مع تعويض درجة الحرارة والتحكم الأوتوماتيكي في التصريف.
  • ثلاث مضخات جرعات وثلاثة خزانات منفصلة للمواد الكيميائية.
  • صمام تصريف كهربائي وعداد مياه تعويضية بخروج نبضي.
  • حساس تدفق وإنذارات لمستوى المواد الكيميائية.
  • صندوق ABS بدرجة حماية IP65 / NEMA 4X.

يتم اختيار سعات المضخات وأحجام الخزانات ومقاسات الصمام والعداد وفقاً لحجم نظام التبريد وشبكة الأنابيب وبرنامج المعالجة الكيميائية.

السعر: 3,500 ريال عماني للتوريد فقط.

لا يشمل السعر التركيب والتشغيل التجريبي والمواد الكيميائية وكابلات التغذية الكهربائية والأعمال المدنية وتمديدات الأنابيب الخارجية.